How Chase BlH2Ock® Strand Fill Fits into a Stranding Line: A162A Standard vs. A162HF High Flow

Written by Chase Corp Editor | 11/16/26, 4:14 PM

Introduction

Water ingress is one of the most persistent threats to long-term cable reliability. For many cable constructions, the defense begins deep inside the cable core—at the strand level—where cable strand fill is introduced during manufacturing. This post explains what a stranding line does, where strand fill fits into that process, and how to think about the difference between two grades of Chase BlH2Ock® strand fill: A162A, the standard grade, and A162HF, the high-flow grade.

The goal here is not to crown one grade as universally superior. Instead, it is to give manufacturing professionals a clear mental model of the process and a set of practical factors to weigh when evaluating which grade may suit a given line and cable design.

What a Stranding Line Does

A stranding line is the production equipment that twists, or strands, multiple individual wires together to form a larger conductor. Instead of relying on a single solid conductor, many power and specialty cables use several smaller wires bundled and twisted into a defined geometry. This stranded construction improves flexibility, handling, and mechanical performance compared with a solid conductor of the same cross-section.

As the individual wires are drawn together and twisted, the line applies controlled tension and lay (the angle and pitch of the twist) to build a consistent, stable conductor. Downstream of the stranding operation, the conductor typically moves on to insulation, additional layering, and jacketing steps.

Where Strand Fill Fits into the Process

When wires are twisted together, small gaps remain between them. These gaps—often called interstitial spaces—are the internal voids between strands. Left open, they can create a continuous pathway that allows water to travel along the length of the cable from a single breach point. This movement of moisture along the conductor is known as longitudinal water migration.

Strand fill is a water-blocking compound introduced into the conductor during the stranding operation to occupy those interstitial spaces. In practice, the fill is applied as the wires come together, so that the voids between strands are filled as the conductor is formed. The purpose is to help block water from migrating along the inside of the conductor, keeping any intrusion localized rather than allowing it to compromise a longer run of cable.

Because the fill is applied in-line during stranding, how the material flows and distributes through the conductor geometry is directly relevant to the manufacturing process—and this is where the distinction between the standard and high-flow grades becomes practically useful.

Comparing Chase BlH2Ock® A162A and A162HF

Chase BlH2Ock® strand fill is offered in more than one grade to support different line configurations and processing needs. The two discussed here are:

  • A162A — Standard grade: The baseline strand fill option within the BlH2Ock® strand fill family.
  • A162HF — High-flow grade: A variant positioned as a high-flow alternative to the standard grade.

Both A162A and A162HF meet the same stringent performance requirements. A162HF’s high-flow designation describes its flow characteristics during application; it does not indicate a different performance standard. Because both grades meet the same requirements, switching from A162A to A162HF does not require requalification. 

The core distinction between the two, as reflected in their naming, is standard versus high flow. In general terms, a "high-flow" strand fill is formulated with flow characteristics intended to influence how the material moves and distributes during application. The practical relevance of that flow behavior depends on your specific line setup, application method, and the geometry of the conductor being produced.

A note on scope: Beyond the standard-versus-high-flow designation, the specific numerical flow rates, operating conditions, and processing parameters for each grade should be confirmed directly against Chase's product documentation for your application. Rather than estimate those values, the comparison below is kept intentionally limited to what the grade designations communicate.

Selection Considerations

Choosing between a standard and a high-flow strand fill is a process decision as much as a material decision. Neither grade is inherently the right choice for every line; the better fit depends on how the material interacts with your equipment and product. Useful factors to weigh include:

  • Line setup: Consider your stranding equipment, line speed, and how the fill is metered and introduced into the conductor as it forms.
  • Application method: The way material is delivered into the interstitial spaces can make flow characteristics more or less relevant to achieving consistent fill.
  • Production requirements: Throughput goals, consistency expectations, and process stability may all influence which flow behavior is preferable.
  • Cable design: Conductor size, number of strands, lay geometry, and the size of the voids to be filled all affect how well a given grade distributes.

The practical question is not "which grade is best?" but rather "which grade behaves predictably in my process and achieves reliable fill for my construction?" That answer is best reached by matching grade behavior to your specific line and design, ideally with validation.

Conclusion and Next Step

Strand fill plays an important role in cable reliability by occupying the gaps between wires during stranding and helping prevent water from traveling along the conductor. Chase BlH2Ock® strand fill is available in A162A, the standard grade, and A162HF, the high-flow grade. Both grades meet the same stringent performance requirements; A162HF differs in its flow characteristics during application. Switching from A162A to A162HF does not require requalification.

The right grade depends on your stranding line, application method, production requirements, and cable design. Contact Chase to review the technical documentation and discuss which grade best fits your application.

Frequently Asked Questions

What is cable strand fill?

Cable strand fill is a compound applied during stranding to occupy spaces between individual wires in a stranded conductor. It helps block water from migrating along the conductor.

What is the difference between Chase BlH2Ock® A162A and A162HF?

 A162A is the standard grade, while A162HF is the high-flow grade. Both meet the same stringent performance requirements; the distinction is their flow characteristics during application. Switching from A162A to A162HF does not require requalification. Contact Chase to confirm any application-specific details. 

Is A162HF better than A162A?

Not necessarily. Neither grade is presented as universally better. The suitable option depends on the line setup, application method, production requirements, and cable design.

How can manufacturers choose the right grade?

Review verified product data and consider the specific stranding line and cable construction. Validate the grade under relevant production conditions, and contact Chase for application-specific guidance.