Choosing the Right CSI Specification for Waterproofing and High-Performance Coatings

Written by CIM Editor | 11/23/2026

Choosing between CSI Section 07 10 00 – Dampproofing and Waterproofing and CSI Section 09 96 00 – High-Performance Coatings begins with the system’s intended function. If the primary purpose is to resist water intrusion, Division 07 may be appropriate. If the system primarily protects a surface from chemicals, abrasion, corrosion, or another demanding exposure, Division 09 may be the better fit.

However, the material or product name alone does not determine the correct section. Design professionals must also consider the substrate, project location, exposure conditions, application requirements, and organization of the complete project manual.

This guide explains the differences between the two sections and the factors architects, engineers, consultants, and specifiers should evaluate before making a selection.

 

What Is the Purpose of a CSI Specification Section? 

CSI MasterFormat is a standardized system for organizing construction information into numbered divisions and sections. Division 07 covers Thermal and Moisture Protection, while Division 09 covers Finishes.

These classifications help project teams locate related requirements throughout the bidding, submittal, construction, and inspection processes. A well-selected section communicates the system’s role and helps connect product requirements with application procedures and field responsibilities.

However, a CSI number is an organizational tool—not a substitute for technical evaluation. Selecting a section does not automatically confirm that a material is appropriate for the substrate, exposure, or expected service conditions.

What Does CSI Section 07 10 00 Cover? 

CSI Section 07 10 00 covers dampproofing and waterproofing. It generally applies when the primary purpose of a system is to resist the passage of water or moisture through a building element or structure.

Project-specific requirements may address:

  • Waterproofing materials and system components
  • Substrate preparation
  • Membrane continuity
  • Cracks, joints, and penetrations
  • Transitions between materials
  • Terminations and flashing
  • Drainage and protection components
  • Application procedures
  • Inspection and testing
  • Protection of completed work

Waterproofing specifications should consider the entire system rather than only the primary membrane. Primers, reinforcing materials, sealants, drainage components, protection materials, and adjoining systems may all affect performance.

What Does CSI Section 09 96 00 Cover? 

CSI Section 09 96 00 covers high-performance coatings. It generally applies when the primary purpose of a coating is to protect a substrate from demanding environmental or service conditions.

These specifications may address:

  • Coating-system components
  • Surface preparation
  • Primers and intermediate coats
  • Finish or protective coats
  • Chemical or corrosion exposure
  • Abrasion and wear
  • Environmental application conditions
  • Mixing and application procedures
  • Wet- and dry-film thickness
  • Curing and recoat requirements
  • Inspection and field quality control
  • Repair of damaged areas

Although high-performance coatings may resist moisture, their primary specified purpose may be broader surface protection rather than preventing water intrusion through an assembly.

What Is the Difference Between CSI 07 10 00 and CSI 09 96 00? 

The primary difference is the intended function of the system.

CSI section

Primary function

Typical specification focus

07 10 00 – Dampproofing and Waterproofing

Resisting water or moisture intrusion

Membrane continuity, penetrations, transitions, terminations, detailing, drainage, and protection

09 96 00 – High-Performance Coatings

Protecting a surface from demanding exposure conditions

Surface preparation, adhesion, coating layers, thickness, chemical exposure, abrasion, corrosion, and finish

The distinction is not always based on whether the material is liquid-applied. A liquid-applied product may function as a waterproofing membrane on one project and as a protective coating on another.

The selected section should reflect what the installed system is expected to accomplish within the specific project.

Which Factors Should Guide Section Selection? 

Intended function

First, determine the system’s primary purpose. Is it intended to prevent water intrusion, protect a substrate from its service environment, or provide both functions?

The primary function usually provides the clearest starting point for choosing between Division 07 and Division 09.

Substrate

Identify whether the system will be applied over concrete, steel, masonry, wood, asphalt, or another material. The substrate influences adhesion, preparation, primer selection, application, and inspection requirements.

Its age and condition should also be considered. New concrete, existing concrete, previously coated steel, and deteriorated masonry may require very different preparation procedures.

Water exposure

Determine whether the system will experience occasional moisture, continuous immersion, hydrostatic pressure, weather exposure, or another type of water contact.

The specification should describe the relevant exposure rather than relying on a general statement that the system must be “waterproof.”

Environmental and chemical exposure

Consider whether the installed system may encounter:

  • Chemicals
  • Corrosive conditions
  • Abrasion
  • UV exposure
  • Temperature changes
  • Pedestrian or vehicular traffic
  • Interior or exterior conditions
  • Continuous or intermittent immersion

These conditions help establish the required performance properties and may point toward a high-performance coating specification.

Project location and detailing

The location of the system within the structure also matters. Below-grade walls, decks, containment areas, tanks, fountains, and exposed structural surfaces may each require different detailing and coordination.

Transitions, drains, penetrations, joints, edges, and terminations should be shown in the drawings and coordinated with the specification.

Related construction trades

Review which contractor or trade is expected to perform the work. The selected section should fit logically within the complete project manual and clearly assign responsibility for preparation, installation, inspection, and protection.

Can Both CSI Sections Be Used on the Same Project? 

Yes. A project may contain separate waterproofing and high-performance coating systems, requiring both CSI 07 10 00 and CSI 09 96 00.

For example, one portion of a structure may require a waterproofing system to resist water intrusion, while another surface requires a high-performance coating to resist chemical exposure or abrasion.

In some cases, a single system may provide both waterproofing and protective functions. The project team should then determine where the system is best specified and coordinate related requirements to avoid duplication, gaps, or conflicting instructions.

Why Should a Manufacturer Specification Be Customized? 

A manufacturer-provided 3-part specification offers an organized technical starting point, but it should be reviewed before being incorporated into a project manual.

The design professional should confirm that the specification reflects:

  • The correct CSI section
  • The selected system and components
  • The project substrate
  • Existing surface conditions
  • Environmental and service exposure
  • Required preparation
  • Application limitations
  • Inspection and testing requirements
  • Relevant drawings and details
  • Related specification sections

Language that does not apply to the project should be removed. Missing project-specific requirements should be added, and all technical information should be checked against current manufacturer documentation.

How Should the Specification Be Coordinated with the Drawings? 

Specifications describe the materials, preparation, application, and quality requirements for the work. Drawings show the system’s location, extent, configuration, and construction details.

The two should communicate the same design intent. Coordination should include:

  • The limits of the system
  • Substrate types
  • Joints and penetrations
  • Changes in plane
  • Drains and terminations
  • Connections to adjoining systems
  • Required protection
  • Trade responsibilities

If the drawings and specifications conflict, contractors may interpret the scope differently. Reviewing both together can help identify unclear or missing requirements before construction begins.

How to Choose the Appropriate CSI Section 

Use the following process when evaluating CSI 07 10 00 and CSI 09 96 00:

  1. Define the primary function. Determine whether the system primarily resists water intrusion or protects the substrate from another service condition.
  2. Identify the substrate. Document its material, condition, moisture, existing coatings, and required preparation.
  3. Evaluate the exposure. Consider water, chemicals, abrasion, corrosion, UV exposure, traffic, immersion, and temperature changes.
  4. Review the location and details. Evaluate transitions, penetrations, joints, terminations, drains, and adjoining systems.
  5. Confirm system components. Coordinate the primary material with its primers, reinforcement, sealants, topcoats, and accessories.
  6. Select the appropriate section. Choose the section that most accurately communicates the system’s primary role.
  7. Customize the specification. Edit the 3-part specification to match the actual project.
  8. Coordinate the documents. Confirm that the written requirements agree with the drawings and related specification sections.
  9. Request technical guidance when needed. Consult the manufacturer or a qualified specification professional when the system’s classification or requirements are unclear.

Frequently Asked Questions 

Is every liquid-applied membrane specified under CSI 07 10 00?

No. The physical form of the material does not determine the section. A liquid-applied system may fall under CSI 07 10 00 when its primary purpose is waterproofing or under CSI 09 96 00 when it primarily functions as a high-performance protective coating.

Can one product be specified in both Division 07 and Division 09?

Potentially, depending on its intended use and documented capabilities. If the same product is used for different purposes, each specification should clearly define the applicable substrate, components, preparation, application, performance, and inspection requirements.

Can a CSI section number replace a technical evaluation?

No. The CSI number organizes the information, but it does not confirm that a product or system is suitable for the project. The design professional must still evaluate function, substrate, exposure, application conditions, and expected performance.

Is CSI 07 10 00 only for below-grade waterproofing?

No. CSI 07 10 00 is not limited to a single project location. The appropriate section and subsection depend on the type of waterproofing system and the way the work is organized within the project documents.

Does a water-resistant coating qualify as waterproofing?

Not necessarily. Water resistance and waterproofing are not automatically interchangeable. The system must be evaluated according to its intended function, tested performance, installation requirements, continuity, and suitability for the expected water exposure.

What belongs in a high-performance coating specification?

A high-performance coating specification may address approved materials, system components, surface preparation, mixing, application, film thickness, curing, environmental limitations, inspection, repair, and protection of completed work.

Should manufacturer-provided specifications be edited?

Yes. Manufacturer-provided specifications should be reviewed and customized for the selected system, substrate, exposure, project details, and related construction requirements.

What if a system provides both waterproofing and protective coating performance?

Determine its primary role within the project and coordinate any secondary performance requirements within the selected section. If the proper location remains unclear, consult the manufacturer or a qualified specification professional.

Where can I request an editable 3-part specification?

Chase Corporation provides editable 3-part specifications for high-performance building solutions. Architects, engineers, designers, consultants, and specifiers can request the appropriate documentation through the Chase Corporation specification request form.

Request the Right Specification for Your Project 

Selecting the appropriate CSI section begins with understanding the system’s function, substrate, exposure, and service conditions. Chase Corporation provides editable Microsoft Word specifications that design professionals can tailor and integrate into their project documents.