Choosing between CSI Section 07 10 00 – Dampproofing and Waterproofing and CSI Section 09 96 00 – High-Performance Coatings begins with the system’s intended function. If the primary purpose is to resist water intrusion, Division 07 may be appropriate. If the system primarily protects a surface from chemicals, abrasion, corrosion, or another demanding exposure, Division 09 may be the better fit.
However, the material or product name alone does not determine the correct section. Design professionals must also consider the substrate, project location, exposure conditions, application requirements, and organization of the complete project manual.
This guide explains the differences between the two sections and the factors architects, engineers, consultants, and specifiers should evaluate before making a selection.
CSI MasterFormat is a standardized system for organizing construction information into numbered divisions and sections. Division 07 covers Thermal and Moisture Protection, while Division 09 covers Finishes.
These classifications help project teams locate related requirements throughout the bidding, submittal, construction, and inspection processes. A well-selected section communicates the system’s role and helps connect product requirements with application procedures and field responsibilities.
However, a CSI number is an organizational tool—not a substitute for technical evaluation. Selecting a section does not automatically confirm that a material is appropriate for the substrate, exposure, or expected service conditions.
CSI Section 07 10 00 covers dampproofing and waterproofing. It generally applies when the primary purpose of a system is to resist the passage of water or moisture through a building element or structure.
Project-specific requirements may address:
Waterproofing specifications should consider the entire system rather than only the primary membrane. Primers, reinforcing materials, sealants, drainage components, protection materials, and adjoining systems may all affect performance.
CSI Section 09 96 00 covers high-performance coatings. It generally applies when the primary purpose of a coating is to protect a substrate from demanding environmental or service conditions.
These specifications may address:
Although high-performance coatings may resist moisture, their primary specified purpose may be broader surface protection rather than preventing water intrusion through an assembly.
The primary difference is the intended function of the system.
|
CSI section |
Primary function |
Typical specification focus |
|
07 10 00 – Dampproofing and Waterproofing |
Resisting water or moisture intrusion |
Membrane continuity, penetrations, transitions, terminations, detailing, drainage, and protection |
|
09 96 00 – High-Performance Coatings |
Protecting a surface from demanding exposure conditions |
Surface preparation, adhesion, coating layers, thickness, chemical exposure, abrasion, corrosion, and finish |
The distinction is not always based on whether the material is liquid-applied. A liquid-applied product may function as a waterproofing membrane on one project and as a protective coating on another.
The selected section should reflect what the installed system is expected to accomplish within the specific project.
First, determine the system’s primary purpose. Is it intended to prevent water intrusion, protect a substrate from its service environment, or provide both functions?
The primary function usually provides the clearest starting point for choosing between Division 07 and Division 09.
Identify whether the system will be applied over concrete, steel, masonry, wood, asphalt, or another material. The substrate influences adhesion, preparation, primer selection, application, and inspection requirements.
Its age and condition should also be considered. New concrete, existing concrete, previously coated steel, and deteriorated masonry may require very different preparation procedures.
Determine whether the system will experience occasional moisture, continuous immersion, hydrostatic pressure, weather exposure, or another type of water contact.
The specification should describe the relevant exposure rather than relying on a general statement that the system must be “waterproof.”
Consider whether the installed system may encounter:
These conditions help establish the required performance properties and may point toward a high-performance coating specification.
The location of the system within the structure also matters. Below-grade walls, decks, containment areas, tanks, fountains, and exposed structural surfaces may each require different detailing and coordination.
Transitions, drains, penetrations, joints, edges, and terminations should be shown in the drawings and coordinated with the specification.
Review which contractor or trade is expected to perform the work. The selected section should fit logically within the complete project manual and clearly assign responsibility for preparation, installation, inspection, and protection.
Yes. A project may contain separate waterproofing and high-performance coating systems, requiring both CSI 07 10 00 and CSI 09 96 00.
For example, one portion of a structure may require a waterproofing system to resist water intrusion, while another surface requires a high-performance coating to resist chemical exposure or abrasion.
In some cases, a single system may provide both waterproofing and protective functions. The project team should then determine where the system is best specified and coordinate related requirements to avoid duplication, gaps, or conflicting instructions.
A manufacturer-provided 3-part specification offers an organized technical starting point, but it should be reviewed before being incorporated into a project manual.
The design professional should confirm that the specification reflects:
Language that does not apply to the project should be removed. Missing project-specific requirements should be added, and all technical information should be checked against current manufacturer documentation.
Specifications describe the materials, preparation, application, and quality requirements for the work. Drawings show the system’s location, extent, configuration, and construction details.
The two should communicate the same design intent. Coordination should include:
If the drawings and specifications conflict, contractors may interpret the scope differently. Reviewing both together can help identify unclear or missing requirements before construction begins.
Use the following process when evaluating CSI 07 10 00 and CSI 09 96 00:
Is every liquid-applied membrane specified under CSI 07 10 00?
No. The physical form of the material does not determine the section. A liquid-applied system may fall under CSI 07 10 00 when its primary purpose is waterproofing or under CSI 09 96 00 when it primarily functions as a high-performance protective coating.
Can one product be specified in both Division 07 and Division 09?
Potentially, depending on its intended use and documented capabilities. If the same product is used for different purposes, each specification should clearly define the applicable substrate, components, preparation, application, performance, and inspection requirements.
Can a CSI section number replace a technical evaluation?
No. The CSI number organizes the information, but it does not confirm that a product or system is suitable for the project. The design professional must still evaluate function, substrate, exposure, application conditions, and expected performance.
Is CSI 07 10 00 only for below-grade waterproofing?
No. CSI 07 10 00 is not limited to a single project location. The appropriate section and subsection depend on the type of waterproofing system and the way the work is organized within the project documents.
Does a water-resistant coating qualify as waterproofing?
Not necessarily. Water resistance and waterproofing are not automatically interchangeable. The system must be evaluated according to its intended function, tested performance, installation requirements, continuity, and suitability for the expected water exposure.
What belongs in a high-performance coating specification?
A high-performance coating specification may address approved materials, system components, surface preparation, mixing, application, film thickness, curing, environmental limitations, inspection, repair, and protection of completed work.
Should manufacturer-provided specifications be edited?
Yes. Manufacturer-provided specifications should be reviewed and customized for the selected system, substrate, exposure, project details, and related construction requirements.
What if a system provides both waterproofing and protective coating performance?
Determine its primary role within the project and coordinate any secondary performance requirements within the selected section. If the proper location remains unclear, consult the manufacturer or a qualified specification professional.
Where can I request an editable 3-part specification?
Chase Corporation provides editable 3-part specifications for high-performance building solutions. Architects, engineers, designers, consultants, and specifiers can request the appropriate documentation through the Chase Corporation specification request form.
Selecting the appropriate CSI section begins with understanding the system’s function, substrate, exposure, and service conditions. Chase Corporation provides editable Microsoft Word specifications that design professionals can tailor and integrate into their project documents.
Request a 3-Part Specification