A complete 3-part specification organizes project requirements into Part 1 – General, Part 2 – Products, and Part 3 – Execution. For waterproofing and high-performance coating projects, this format helps architects, engineers, and specifiers coordinate material selection, surface preparation, application, inspection, and quality-control requirements.
CSI Section 07 10 00 addresses dampproofing and waterproofing, while CSI Section 09 96 00 addresses high-performance coatings. Chase Corporation provides editable 3-part specifications that design professionals can adapt to the substrates, exposures, service conditions, and performance requirements of individual projects.
This guide explains what belongs in each part of a specification, how the two CSI sections differ, and how editable specifications can simplify the design and documentation process.
A 3-part specification is a standardized format used to organize technical construction requirements. It divides the information into three sections:
This structure gives every requirement a defined location. It allows architects, engineers, contractors, installers, and inspectors to find relevant information more efficiently and understand what is required throughout the project.
A complete specification also connects the selected system with the conditions under which it will be installed. This is particularly important for waterproofing membranes and high-performance coatings, where substrate conditions, surface preparation, environmental conditions, and application procedures can directly affect system performance.
Part 1 – General establishes the administrative and procedural requirements for the work before materials are installed.
Depending on the project, Part 1 may address:
Clear Part 1 language helps project teams understand their responsibilities before work begins. It can also establish what documentation must be submitted, how materials should be stored, and which site conditions must be evaluated before installation.
These requirements should be coordinated with the project drawings, Division 01 requirements, manufacturer instructions, and other related sections.
Part 2 – Products identifies the materials and system components that may be used on the project. It may also define the performance requirements those materials must meet.
This section may include:
Part 2 should treat the waterproofing membrane or coating as part of a complete system. Primers, reinforcing materials, sealants, topcoats, and other accessories should be evaluated for compatibility instead of being selected independently.
Product requirements should also reflect the actual project environment. The substrate, anticipated exposure, contact with water or chemicals, temperature conditions, UV exposure, traffic, and required finish may all influence system selection.
Part 3 – Execution explains how the specified system should be examined, prepared, installed, inspected, and protected in the field.
Typical Part 3 requirements include:
Surface preparation should receive particular attention. Even a properly selected material may not perform as intended if it is applied over a contaminated, weak, damp, or otherwise unsuitable surface.
The specification should identify the preparation and acceptance requirements that apply to the selected system and substrate. These requirements should remain consistent with the manufacturer’s current instructions and the conditions found at the project site.
CSI Section 07 10 00 and CSI Section 09 96 00 organize different types of project requirements. The correct section depends primarily on the system’s intended function and the project scope.
|
CSI section |
Primary focus |
Common considerations |
|
07 10 00 – Dampproofing and Waterproofing |
Systems primarily intended to resist water intrusion |
Membrane continuity, substrate conditions, penetrations, joints, transitions, detailing, and exposure to water |
|
09 96 00 – High-Performance Coatings |
Coatings used where enhanced surface protection or performance is required |
Surface preparation, environmental or chemical exposure, coating components, film thickness, application conditions, and finish requirements |
Some systems may provide both waterproofing and protective coating benefits. In those cases, the design professional should consider the primary function of the system, the location of the work, related construction trades, and the organization of the complete project manual.
The CSI section number should not replace a technical evaluation of the project. The substrate, exposure, detailing, installation conditions, and expected performance must still be considered.
A complete 3-part specification gives the project team a common source for administrative, product, and installation requirements.
|
Incomplete or narrative requirements |
Complete 3-part specification |
|
Requirements may be scattered across documents |
Information is organized into General, Products, and Execution |
|
Product and installation requirements may overlap |
Each type of requirement has a defined location |
|
Surface preparation may lack sufficient detail |
Preparation and application are addressed in Part 3 |
|
Accessory products may be selected separately |
System components can be coordinated in Part 2 |
|
Generic wording may require extensive revision |
Editable language provides a structured starting point |
|
Field acceptance may be unclear |
Inspection and quality-control requirements can be defined |
The specification should still be reviewed alongside the drawings and details. Transitions, terminations, drains, penetrations, joints, and changes in substrate must be coordinated across all relevant project documents.
An editable 3-part specification provides a structured starting point for the design professional. Rather than drafting an entire technical section from a blank document, the specifier can review existing language and tailor it to the project.
Chase Corporation provides its specifications in Microsoft Word format, allowing architects, engineers, and designers to:
A manufacturer-provided specification should not be inserted into a project manual without review. It must be edited to reflect the project’s substrate, exposure, service conditions, selected system, applicable standards, and related construction requirements.
Use the following process to convert a general specification into a project-relevant document.
1. Confirm the scope and CSI section
Determine whether the system is being specified primarily for waterproofing, high-performance surface protection, or a combination of functions. Review how the work relates to other specification sections and construction trades.
2. Identify the substrate
Document whether the system will be installed over concrete, steel, masonry, wood, asphalt, or another material. Consider the age, condition, moisture level, profile, cleanliness, and previous treatment of the substrate.
3. Define the service environment
Evaluate the conditions the completed system may encounter, such as:
4. Coordinate all system components
Review the membrane or coating together with its required primers, reinforcement, sealants, topcoats, and accessories. Confirm that the specification addresses a compatible system rather than a collection of unrelated products.
5. Establish surface-preparation requirements
Specify the cleaning, repair, profiling, and examination procedures appropriate for the substrate and selected system. Include measurable acceptance requirements when they are supported by the applicable technical documentation.
6. Review application conditions
Coordinate mixing, application method, environmental limitations, recoat requirements, thickness, curing, inspection, and protection with the manufacturer’s current instructions.
7. Coordinate the specification with the drawings
Confirm that details for penetrations, joints, edges, transitions, terminations, drains, and adjoining systems agree with the written specification.
Several common issues can weaken waterproofing and coating specifications:
Reviewing these items during design can help create a more coordinated and project-specific specification.
What is a 3-part construction specification?
A 3-part construction specification organizes project requirements into Part 1 – General, Part 2 – Products, and Part 3 – Execution. Together, these sections address administrative procedures, acceptable materials, system components, surface preparation, application, inspection, and protection.
What does CSI Section 07 10 00 cover?
CSI Section 07 10 00 covers dampproofing and waterproofing. Project-specific content may address waterproofing materials, substrate requirements, joints, transitions, penetrations, application procedures, inspection, and protection of completed work.
What does CSI Section 09 96 00 cover?
CSI Section 09 96 00 covers high-performance coatings. Specifications in this section may include coating-system components, substrate preparation, environmental conditions, application requirements, film thickness, inspection, and quality-control procedures.
What is the difference between waterproofing and a high-performance coating?
A waterproofing system is primarily intended to resist water intrusion. A high-performance coating is generally selected to protect a surface against specific environmental, chemical, or service conditions. Some systems may provide both functions, so the appropriate section should be selected according to the project scope and the system’s primary intended use.
Can CSI 07 10 00 and CSI 09 96 00 both apply to one project?
Yes. A project may contain separate waterproofing and high-performance coating requirements, or it may involve systems with overlapping protective functions. The design professional should coordinate the sections to prevent conflicting or duplicated requirements.
What information belongs in each part of the specification?
Part 1 addresses administrative and procedural requirements. Part 2 identifies acceptable products, materials, manufacturers, system components, and performance criteria. Part 3 establishes examination, preparation, application, inspection, repair, and protection requirements.
Can a manufacturer-provided specification be used without editing?
No manufacturer-provided specification should be treated as automatically project-ready. It should be reviewed and customized to match the selected system, substrate, details, exposure conditions, performance requirements, and other project documents.
Why are editable specifications helpful?
Editable specifications give architects, engineers, and specifiers an organized technical starting point. They can revise the language to match the project without drafting the entire section from the beginning.
What should be reviewed before selecting a waterproofing or coating system?
The design professional should review the substrate, intended function, environmental and chemical exposure, water conditions, application environment, detailing, maintenance expectations, and required performance. Product selection should be coordinated with current technical documentation and project-specific requirements.
Where can I request a 3-part waterproofing or coating specification?
Chase Corporation provides editable 3-part specifications for high-performance building solutions. Architects, engineers, designers, and specifiers can request the appropriate documentation through the Chase Corporation specification request form.
Accurate specifications begin with a clear understanding of the substrate, exposure, service conditions, and intended system performance. Chase Corporation provides editable Microsoft Word specifications that design professionals can customize and integrate into their project documents.
Request a 3-Part Specification