Identifying termination points and properly terminating waterproof coatings are two critical aspects of a waterproofing system’s long-term success. Whether you are applying the coating system to a roof, floor, tank, or fountain; in hot or cold climates; or to concrete, wood, steel, or any other construction materials, correctly terminating the waterproofing system is essential.
Termination points are areas where the waterproofing membrane stops or is no longer applied. Seasoned waterproofing applicators will identify, plan, and physically mark out where they will terminate the membrane to avoid surprises during application and ensure the product performs as designed.
Most waterproofing membrane systems recommend terminating a minimum of 8 - 12 inches above, away from, or beyond critical areas. Critical areas are physical locations on the job that pose the most significant risk to waterproofing failure. Waterproofing membranes that end at or below critical points are vulnerable to moisture infiltration because water can enter behind the membrane and continue to migrate, causing further damage. This practice of termination is common for most waterproofing systems, including self-adhered, single-ply, and liquid-applied systems.
Examples of critical areas:
Related Article: Comparing Waterproofing Systems: Cold Fluid Applied vs Self-Adhered Sheet Membrane
Manufacturers of waterproof coatings have written instructions for the best means and methods to terminate their coating systems. It's essential to consult with the manufacturer for their specific requirements. Self-adhered, single-ply, and liquid-applied systems are examples of coating systems that terminate in one or more of the following manners:
Note: When working with liquid-applied waterproof coatings, it is essential to maintain uniform thickness at the termination point and avoid feathering the membrane.
Related Article: Common Waterproofing Mistakes
In conclusion, it's always best to plan your application and terminations per the manufacturer's written instructions and recommendations.